A rapid and reliable method for Pb isotopic analysis of peat and lichens by laser ablation-quadrupole-inductively coupled plasma-mass spectrometry for biomonitoring and sample screening

Kylander, Malin E. (författare)
Stockholms universitet,Institutionen för geologi och geokemi
Weiss, Dominik (författare)
Jeffries, Teresa (författare)
visa fler...
Kober, Bernd (författare)
Dolgopolova, Alla (författare)
Garcia-Sanchez, Raquel (författare)
Coles, Barry J. (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2007
2007
Svenska.
Ingår i: Analytica Chimica Acta. - : Elsevier BV. - 0003-2670. ; 582:1, s. 116-124
  • Tidskriftsartikel (populärvet., debatt m.m.)
Abstract Ämnesord
Stäng  
  • An analytical protocol for rapid and reliable laser ablation-quadrupole (LA-Q)- and multi-collector (MC-) inductively coupled plasma-mass spectrometry (ICP-MS) analysis of Pb isotope ratios (207Pb/206Pb and 208Pb/206Pb) in peats and lichens is developed. This technique is applicable to source tracing atmospheric Pb deposition in biomonitoring studies and sample screening. Reference materials and environmental samples were dry ashed and pressed into pellets for introduction by laser ablation. No binder was used to reduce contamination. LA-MC-ICP-MS internal and external precisions were <1.1% and <0.3%, respectively, on both 207Pb/206Pb and 208Pb/206Pb ratios. LA-Q-ICP-MS internal precisions on 207Pb/206Pb and 208Pb/206Pb ratios were lower with values for the different sample sets <14.3% while external precisions were <2.9%. The level of external precision acquired in this study is high enough to distinguish between most modern Pb sources. LA-MC-ICP-MS measurements differed from thermal ionisation mass spectrometry (TIMS) values by 1% or less while the accuracy obtained using LA-Q-ICP-MS compared to solution MC-ICP-MS was 3.1% or better using a run bracketing (RB) mass bias correction method. Sample heterogeneity and detector switching when measuring 208Pb by Q-ICP-MS are identified as sources of reduced analytical performance.

Nyckelord

Laser ablation
Pb isotope
Environmental monitoring
Multi-collector
Biological sample
Peat
Lichen

Publikations- och innehållstyp

pop (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy