SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sandgren J)
 

Sökning: WFRF:(Sandgren J) > Assessment of wear ...

  • Sandgren, B.Karolinska Institute, Sweden (författare)

Assessment of wear and periacetabular osteolysis using dual energy computed tomography on a pig cadaver to identify the lowest acceptable radiation dose

  • Artikel/kapitelEngelska2016

Förlag, utgivningsår, omfång ...

  • BRITISH EDITORIAL SOC BONE JOINT SURGERY,2016
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-131188
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-131188URI
  • https://doi.org/10.1302/2046-3758.57.2000566DOI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:134010995URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Objectives Computed tomography (CT) plays an important role in evaluating wear and periacetabular osteolysis (PAO) in total hip replacements. One concern with CT is the high radiation exposure since standard pelvic CT provides approximately 3.5 millisieverts (mSv) of radiation exposure, whereas a planar radiographic examination with three projections totals approximately 0.5 mSv. The objective of this study was to evaluate the lowest acceptable radiation dose for dual-energy CT (DECT) images when measuring wear and periacetabular osteolysis in uncemented metal components. Materials and Methods A porcine pelvis with bilateral uncemented hip prostheses and with known linear wear and acetabular bone defects was examined in a third-generation multidetector DECT scanner. The examinations were performed with four different radiation levels both with and without iterative reconstruction techniques. From the high and low peak kilo voltage acquisitions, polychrmoatic images were created together with virtual monochromatic images of energies 100 kiloelectron volts (keV) and 150 keV. Results We could assess wear and PAO while substantially lowering the effective radiation dose to 0.7 mSv for a total pelvic view with an accuracy of around 0.5 mm for linear wear and 2 mm to 3 mm for PAO. Conclusion CT for detection of prosthetic wear and PAO could be used with clinically acceptable accuracy at a radiation exposure level equal to plain radiographic exposures.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Skorpil, M.Karolinska Institutet,Karolinska Institute, Sweden (författare)
  • Nowik, P.Karolinska Institute, Sweden; Karolinska University Hospital, Sweden (författare)
  • Olivecrona, H.Karolinska Institute, Sweden (författare)
  • Crafoord, J.Karolinska Institute, Sweden; Ersta Hospital, Sweden (författare)
  • Weidenhielm, L.Karolinska Institutet,Karolinska Institute, Sweden; Karolinska Institute, Sweden (författare)
  • Persson, AndersLinköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Röntgenkliniken i Linköping,Karolinska Institute, Sweden(Swepub:liu)andpe75 (författare)
  • Karolinska InstitutetKarolinska Institute, Sweden (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Bone & Joint Research: BRITISH EDITORIAL SOC BONE JOINT SURGERY5:7, s. 307-3132046-3758

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy