SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Östli Per 1979)
 

Sökning: WFRF:(Östli Per 1979) > Study of the Feasib...

Study of the Feasible Size of a Bone Conduction Implant Transducer in the Temporal Bone

Reinfeldt, Sabine, 1978 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Östli, Per, 1979 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Håkansson, Bo, 1953 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Taghavi, Hamidreza, 1981 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Eeg-Olofsson, Måns, 1967 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för öron-, näs- och halssjukdomar,Institute of Clinical Sciences, Department of Otorhinolaryngology,University of Gothenburg
Stalfors, Joacim, 1966 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för öron-, näs- och halssjukdomar,Institute of Clinical Sciences, Department of Otorhinolaryngology,University of Gothenburg
visa färre...
 (creator_code:org_t)
2015
2015
Engelska.
Ingår i: Otology and Neurotology. - 1531-7129 .- 1537-4505. ; 36:4, s. 631-637
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Hypothesis: The aim was to assess the temporal bone volume to determine the suitable size and position of a bone conduction implant (BCI) transducer. Background: A BCI transducer needs to be sufficiently small to fit in the mastoid portion of the temporal bone for a majority of patients. The anatomical geometry limits both the dimension of an implanted transducer and its positions in the temporal bone to provide a safe and simple surgery. Methods: Computed tomography (CT) scans of temporal bones from 22 subjects were virtually reconstructed. With an algorithm in MATLAB, the maximum transducer diameter as function of the maximum transducer depth in the temporal bone, and the most suitable position were calculated in all subjects. Results: An implanted transducer diameter of 16 mm inserted at a depth of 4 mm statistically fitted 95% of the subjects. If changing the transducer diameter to 12 mm, a depth of 6 mm would fit in 95% of the subjects. The most suitable position was found to be around 20 mm behind the ear canal. Conclusion: The present BCI transducer casing, used in ongoing clinical trials, was designed from the results in this study, demonstrating that the present BCI transducer casing (largest diameter [diagonal]: 15.5 mm, height: 6.4 mm) will statistically fit more than 95% of the subjects. Hence, the present BCI transducer is concluded to be sufficiently small to fit most normal-sized temporal bones and should be placed approximately 20 mm behind the ear canal.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oto-rhino-laryngologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Otorhinolaryngology (hsv//eng)

Nyckelord

Bone conduction
implant
Computed tomography
Maximum size
Temporal bone
Transducer
Bone conduction

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy