2451 0a Study of the Feasible Size of a Bone Conduction Implant Transducer in the Temporal Bone
264 1c 2015
520 a Hypothesis: The aim was to assess the temporal bone volume to determine the suitable size and position of a bone conduction implant (BCI) transducer. Background: A BCI transducer needs to be sufficiently small to fit in the mastoid portion of the temporal bone for a majority of patients. The anatomical geometry limits both the dimension of an implanted transducer and its positions in the temporal bone to provide a safe and simple surgery. Methods: Computed tomography (CT) scans of temporal bones from 22 subjects were virtually reconstructed. With an algorithm in MATLAB, the maximum transducer diameter as function of the maximum transducer depth in the temporal bone, and the most suitable position were calculated in all subjects. Results: An implanted transducer diameter of 16 mm inserted at a depth of 4 mm statistically fitted 95% of the subjects. If changing the transducer diameter to 12 mm, a depth of 6 mm would fit in 95% of the subjects. The most suitable position was found to be around 20 mm behind the ear canal. Conclusion: The present BCI transducer casing, used in ongoing clinical trials, was designed from the results in this study, demonstrating that the present BCI transducer casing (largest diameter [diagonal]: 15.5 mm, height: 6.4 mm) will statistically fit more than 95% of the subjects. Hence, the present BCI transducer is concluded to be sufficiently small to fit most normal-sized temporal bones and should be placed approximately 20 mm behind the ear canal.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Oto-rhino-laryngologi0 (SwePub)302182 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Otorhinolaryngology0 (SwePub)302182 hsv//eng
653 a Bone conduction
653 a implant
653 a Computed tomography
653 a Maximum size
653 a Temporal bone
653 a Transducer
653 a Bone conduction
700a Östli, Per,d 1979u Chalmers tekniska högskola,Chalmers University of Technology4 aut0 (Swepub:cth)ostli
700a Håkansson, Bo,d 1953u Chalmers tekniska högskola,Chalmers University of Technology4 aut0 (Swepub:cth)boh
700a Taghavi, Hamidreza,d 1981u Chalmers tekniska högskola,Chalmers University of Technology4 aut0 (Swepub:cth)taghavi
700a Eeg-Olofsson, Måns,d 1967u Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för öron-, näs- och halssjukdomar,Institute of Clinical Sciences, Department of Otorhinolaryngology,University of Gothenburg4 aut0 (Swepub:gu)xeegma
700a Stalfors, Joacim,d 1966u Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för öron-, näs- och halssjukdomar,Institute of Clinical Sciences, Department of Otorhinolaryngology,University of Gothenburg4 aut0 (Swepub:gu)xstalj
710a Chalmers tekniska högskolab Institutionen för kliniska vetenskaper, Avdelningen för öron-, näs- och halssjukdomar4 org
773t Otology and Neurotologyg 36:4, s. 631-637q 36:4<631-637x 1531-7129x 1537-4505
856u http://dx.doi.org/10.1097/MAO.0000000000000682y FULLTEXT
8564 8u https://gup.ub.gu.se/publication/213128
8564 8u https://doi.org/10.1097/MAO.0000000000000682
8564 8u https://research.chalmers.se/publication/213128

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy