SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Cesarini Kristina G)
 

Search: WFRF:(Cesarini Kristina G) > Evaluation of Mieth...

Evaluation of Miethke M.scio Device Implantation for Intracranial Pressure Monitoring in Patients with Cerebrospinal Fluid Disorders

Jirlow, Unni (author)
Uppsala universitet,Neurokirurgi
Arvidsson, Lisa (author)
Karolinska Univ Hosp, Karolinska Inst, Dept Clin Neurosci, Sect Neurosurg, Stockholm, Sweden.
Magneli, Sara (author)
Uppsala universitet,Neurokirurgi
show more...
Cesarini, Kristina G (author)
Uppsala universitet,Neurokirurgi
Rostami, Elham, 1979- (author)
Uppsala universitet,Neurokirurgi,Karolinska Inst, Dept Neurosci, Stockholm, Sweden.
show less...
 (creator_code:org_t)
Elsevier, 2023
2023
English.
In: World Neurosurgery. - : Elsevier. - 1878-8750 .- 1878-8769. ; 179, s. E63-E74
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • BACKGROUND: Patients with complex shunt-related problems and varying diagnoses of cerebrospinal fluid (CSF) disturbance can present with headache and clinical symptoms that may be difficult to relate to underdrainage or overdrainage. Telemetric intracranial pressure (ICP) monitoring may assist in evaluating individual patients and assessing shunt function and adjustment. We report a case series of patients receiving a Miethke M.scio sensor.METHODS: Between June 2016 and August 2021, 14 patients older than 18 years with different diagnoses underwent ventriculoperitoneal shunt surgery and received a Miethke M.scio sensor.RESULTS: Patients had idiopathic intracranial hyper-tension (n = 3), obstructive hydrocephalus caused by tumors (n = 4), and malformations (n = 5). Headaches (71%) and visual impairment (50%) were the most common symptoms before surgery and 65% of the symptoms were improved after surgery. In total, 25 measurements were made and 11 of these led to changes in the shunt settings. Postoperative measurements were taken in 8 patients and the most common indication of ICP measurement was headache and/or control of the shunt settings.CONCLUSIONS: The Miethke M.scio is a safe and valuable device to use in shunt-treated patients, in particular those expected to need assessment of ICP monitoring postoperatively. Repeated ICP measurements can also assist in personalized adjustment of the shunt setting to optimize CSF flow in this diverse patient group. Future studies should include a standardized protocol with ICP measurements correlated to the symptoms and cause of CSF disturbances to provide better understanding of the dynamics of the ICP in each patient.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Neurologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Neurology (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Keyword

Intracranial pressure
Miethke M.scio
Telemetric ICP measurement

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Jirlow, Unni
Arvidsson, Lisa
Magneli, Sara
Cesarini, Kristi ...
Rostami, Elham, ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Neurology
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Surgery
Articles in the publication
World Neurosurge ...
By the university
Uppsala University
Karolinska Institutet

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view