Sökning: WFRF:(Papagiannis J) > GEC-ESTRO ACROP rec...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 03855naa a2200433 4500 | |
001 | oai:DiVA.org:liu-190227 | |
003 | SwePub | |
008 | 221130s2022 | |||||||||||000 ||eng| | |
009 | oai:prod.swepub.kib.ki.se:151151944 | |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-1902272 URI |
024 | 7 | a https://doi.org/10.1016/j.radonc.2022.09.0122 DOI |
024 | 7 | a http://kipublications.ki.se/Default.aspx?queryparsed=id:1511519442 URI |
040 | a (SwePub)liud (SwePub)ki | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a Perez-Calatayud, Joseu La Fe Hosp, Spain; Clin Benidorm Hosp, Spain; Univ Valencia UV, Spain4 aut |
245 | 1 0 | a GEC-ESTRO ACROP recommendations on calibration and traceability of HE HDR-PDR photon-emitting brachytherapy sources at the hospital level |
264 | 1 | b Elsevier Ireland Ltd,c 2022 |
338 | a electronic2 rdacarrier | |
500 | a Funding Agencies|Spanish "Ministerio de Ciencia e Innovacion" (MCIN) - MCIN/AEI [PID2021-125096NB-I00]; "Generalitat Valenciana" (GVA) [PROMETEO/2021/064] | |
520 | a The vast majority of radiotherapy departments in Europe using brachytherapy (BT) perform temporary implants of high-or pulsed-dose rate (HDR-PDR) sources with photon energies higher than 50 keV. Such techniques are successfully applied to diverse pathologies and clinical scenarios. These recommen-dations are the result of Working Package 21 (WP-21) initiated within the BRAchytherapy PHYsics Quality Assurance System (BRAPHYQS) GEC-ESTRO working group with a focus on HDR-PDR source cal-ibration. They provide guidance on the calibration of such sources, including practical aspects and issues not specifically accounted for in well-accepted societal recommendations, complementing the BRAPHYQS WP-18 Report dedicated to low energy BT photon emitting sources (seeds). The aim of this report is to provide a European-wide standard in HDR-PDR BT source calibration at the hospital level to maintain high quality patient treatments. (c) 2022 The Authors. Published by Elsevier B.V. Radiotherapy and Oncology 176 (2022) 108-117 This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). | |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng |
653 | a Brachytherapy; High energy; Calibration; Dosimetry; HDR-PDR | |
700 | 1 | a Ballester, Facundou Univ Valencia UV, Spain; Univ Valencia UV, Spain4 aut |
700 | 1 | a Carlsson Tedgren, Åsau Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Karolinska Inst, Sweden; Univ Wisconsin, WI USA4 aut0 (Swepub:liu)asaca90 |
700 | 1 | a DeWerd, Larry A.u Univ Wisconsin, WI USA4 aut |
700 | 1 | a Papagiannis, Panagiotisu Natl & Kapodistrian Univ Athens, Greece4 aut |
700 | 1 | a Rivard, Mark J.u Alpert Med Sch Brown Univ, RI USA4 aut |
700 | 1 | a Siebert, Frank-Andreu Klin Strahlentherapie Radioonkol, Germany4 aut |
700 | 1 | a Vijande, Javieru Univ Valencia UV, Spain4 aut |
710 | 2 | a La Fe Hosp, Spain; Clin Benidorm Hosp, Spain; Univ Valencia UV, Spainb Univ Valencia UV, Spain; Univ Valencia UV, Spain4 org |
773 | 0 | t Radiotherapy and Oncologyd : Elsevier Ireland Ltdg 176, s. 108-117q 176<108-117x 0167-8140x 1879-0887 |
856 | 4 | u https://liu.diva-portal.org/smash/get/diva2:1714673/FULLTEXT01.pdfx primaryx Raw objecty fulltext:print |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-190227 |
856 | 4 8 | u https://doi.org/10.1016/j.radonc.2022.09.012 |
856 | 4 8 | u http://kipublications.ki.se/Default.aspx?queryparsed=id:151151944 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.