SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Papagiannis J)
 

Sökning: WFRF:(Papagiannis J) > GEC-ESTRO ACROP rec...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00003855naa a2200433 4500
001oai:DiVA.org:liu-190227
003SwePub
008221130s2022 | |||||||||||000 ||eng|
009oai:prod.swepub.kib.ki.se:151151944
024a https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-1902272 URI
024a https://doi.org/10.1016/j.radonc.2022.09.0122 DOI
024a http://kipublications.ki.se/Default.aspx?queryparsed=id:1511519442 URI
040 a (SwePub)liud (SwePub)ki
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Perez-Calatayud, Joseu La Fe Hosp, Spain; Clin Benidorm Hosp, Spain; Univ Valencia UV, Spain4 aut
2451 0a GEC-ESTRO ACROP recommendations on calibration and traceability of HE HDR-PDR photon-emitting brachytherapy sources at the hospital level
264 1b Elsevier Ireland Ltd,c 2022
338 a electronic2 rdacarrier
500 a Funding Agencies|Spanish "Ministerio de Ciencia e Innovacion" (MCIN) - MCIN/AEI [PID2021-125096NB-I00]; "Generalitat Valenciana" (GVA) [PROMETEO/2021/064]
520 a The vast majority of radiotherapy departments in Europe using brachytherapy (BT) perform temporary implants of high-or pulsed-dose rate (HDR-PDR) sources with photon energies higher than 50 keV. Such techniques are successfully applied to diverse pathologies and clinical scenarios. These recommen-dations are the result of Working Package 21 (WP-21) initiated within the BRAchytherapy PHYsics Quality Assurance System (BRAPHYQS) GEC-ESTRO working group with a focus on HDR-PDR source cal-ibration. They provide guidance on the calibration of such sources, including practical aspects and issues not specifically accounted for in well-accepted societal recommendations, complementing the BRAPHYQS WP-18 Report dedicated to low energy BT photon emitting sources (seeds). The aim of this report is to provide a European-wide standard in HDR-PDR BT source calibration at the hospital level to maintain high quality patient treatments. (c) 2022 The Authors. Published by Elsevier B.V. Radiotherapy and Oncology 176 (2022) 108-117 This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng
653 a Brachytherapy; High energy; Calibration; Dosimetry; HDR-PDR
700a Ballester, Facundou Univ Valencia UV, Spain; Univ Valencia UV, Spain4 aut
700a Carlsson Tedgren, Åsau Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Karolinska Inst, Sweden; Univ Wisconsin, WI USA4 aut0 (Swepub:liu)asaca90
700a DeWerd, Larry A.u Univ Wisconsin, WI USA4 aut
700a Papagiannis, Panagiotisu Natl & Kapodistrian Univ Athens, Greece4 aut
700a Rivard, Mark J.u Alpert Med Sch Brown Univ, RI USA4 aut
700a Siebert, Frank-Andreu Klin Strahlentherapie Radioonkol, Germany4 aut
700a Vijande, Javieru Univ Valencia UV, Spain4 aut
710a La Fe Hosp, Spain; Clin Benidorm Hosp, Spain; Univ Valencia UV, Spainb Univ Valencia UV, Spain; Univ Valencia UV, Spain4 org
773t Radiotherapy and Oncologyd : Elsevier Ireland Ltdg 176, s. 108-117q 176<108-117x 0167-8140x 1879-0887
856u https://liu.diva-portal.org/smash/get/diva2:1714673/FULLTEXT01.pdfx primaryx Raw objecty fulltext:print
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-190227
8564 8u https://doi.org/10.1016/j.radonc.2022.09.012
8564 8u http://kipublications.ki.se/Default.aspx?queryparsed=id:151151944

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy