SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sloboda M.)
 

Sökning: WFRF:(Sloboda M.) > AAPM WGDCAB Report ...

  • Beaulieu, LucCHU Quebec Univ Laval, Canada; Univ Laval, Canada (författare)

AAPM WGDCAB Report 372: A joint AAPM, ESTRO, ABG, and ABS report on commissioning of model-based dose calculation algorithms in brachytherapy

  • Artikel/kapitelEngelska2023

Förlag, utgivningsår, omfång ...

  • WILEY,2023
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-196678
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-196678URI
  • https://doi.org/10.1002/mp.16571DOI
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:153133928URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Funding Agencies|Natural Sciences and Engineering Research Council of Canada (NSERC; FEDER/MCIyU-AEI; Generalitat Valanciana [PGC2018-101302-B, PID2021-125096NB-I00]; NCI [PROMOTEO/2021/064]; Swedish Cancer Foundation [5P30CA056036-17, 5U24CA180803]; [CAN/2017/1029]; [21 1788 Pj]
  • The introduction of model-based dose calculation algorithms (MBDCAs) in brachytherapy provides an opportunity for a more accurate dose calculation and opens the possibility for novel, innovative treatment modalities. The joint AAPM, ESTRO, and ABG Task Group 186 (TG-186) report provided guidance to early adopters. However, the commissioning aspect of these algorithms was described only in general terms with no quantitative goals. This report, from the Working Group on Model-Based Dose Calculation Algorithms in Brachytherapy, introduced a field-tested approach to MBDCA commissioning. It is based on a set of well-characterized test cases for which reference Monte Carlo (MC) and vendor-specific MBDCA dose distributions are available in a Digital Imaging and Communications in Medicine-Radiotherapy (DICOM-RT) format to the clinical users. The key elements of the TG-186 commissioning workflow are now described in detail, and quantitative goals are provided. This approach leverages the well-known Brachytherapy Source Registry jointly managed by the AAPM and the Imaging and Radiation Oncology Core (IROC) Houston Quality Assurance Center (with associated links at ESTRO) to provide open access to test cases as well as step-by-step user guides. While the current report is limited to the two most widely commercially available MBDCAs and only for Ir-192-based afterloading brachytherapy at this time, this report establishes a general framework that can easily be extended to other brachytherapy MBDCAs and brachytherapy sources. The AAPM, ESTRO, ABG, and ABS recommend that clinical medical physicists implement the workflow presented in this report to validate both the basic and the advanced dose calculation features of their commercial MBDCAs. Recommendations are also given to vendors to integrate advanced analysis tools into their brachytherapy treatment planning system to facilitate extensive dose comparisons. The use of the test cases for research and educational purposes is further encouraged.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Ballester, FacundoIIS La Fe Univ Valencia, Spain (författare)
  • Granero, DomingoIIS La Fe Univ Valencia, Spain (författare)
  • Carlsson Tedgren, ÅsaLinköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Karolinska Univ Hosp, Sweden; Karolinska Inst, Sweden(Swepub:liu)asaca90 (författare)
  • Haworth, AnnetteUniv Sydney, Australia (författare)
  • Lowenstein, Jessica R.UT MD Anderson Canc Ctr, TX USA (författare)
  • Ma, YunzhiCHU Quebec Univ Laval, Canada; Univ Laval, Canada (författare)
  • Mourtada, FirasThomas Jefferson Univ, PA USA (författare)
  • Papagiannis, PanagiotisNatl & Kapodistrian Univ Athens, Greece (författare)
  • Rivard, Mark J.Brown Univ, RI USA (författare)
  • Siebert, Frank-AndreUniv Hosp Schleswig Holstein, Germany (författare)
  • Sloboda, Ron S.Cross Canc Inst, Canada; Univ Alberta, Canada (författare)
  • Smith, Ryan L.Alfred Hosp, Australia (författare)
  • Thomson, Rowan M.Carleton Univ, Canada (författare)
  • Verhaegen, FrankMaastricht Univ, Netherlands (författare)
  • Fonseca, GabrielMaastricht Univ, Netherlands (författare)
  • Vijande, JavierIIS La Fe Univ Valencia, Spain; IFIC UV CSIC, Spain (författare)
  • CHU Quebec Univ Laval, Canada; Univ Laval, CanadaIIS La Fe Univ Valencia, Spain (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Medical physics (Lancaster): WILEY50:8, s. E946-E9600094-2405
  • Ingår i:Medical physics: WILEY50:8, s. E946-E9602473-4209

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy