SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Vogt L.)
 

Sökning: WFRF:(Vogt L.) > (2015-2019) > Current use of imag...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00005790naa a2201105 4500
001oai:gup.ub.gu.se/242047
003SwePub
008240528s2016 | |||||||||||000 ||eng|
024a https://gup.ub.gu.se/publication/2420472 URI
024a https://doi.org/10.1111/epi.133472 DOI
040 a (SwePub)gu
041 a eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Mouthaan, B. E.4 aut
2451 0a Current use of imaging and electromagnetic source localization procedures in epilepsy surgery centers across Europe
264 c 2016-03-25
264 1b Wiley,c 2016
520 a Objective: In 2014 the European Union-funded E-PILEPSY project was launched to improve awareness of, and accessibility to, epilepsy surgery across Europe. We aimed to investigate the current use of neuroimaging, electromagnetic source localization, and imaging postprocessing procedures in participating centers. Methods: A survey on the clinical use of imaging, electromagnetic source localization, and postprocessing methods in epilepsy surgery candidates was distributed among the 25 centers of the consortium. A descriptive analysis was performed, and results were compared to existing guidelines and recommendations. Results: Response rate was 96%. Standard epilepsy magnetic resonance imaging (MRI) protocols are acquired at 3 Tesla by 15 centers and at 1.5 Tesla by 9 centers. Three centers perform 3T MRI only if indicated. Twenty-six different MRI sequences were reported. Six centers follow all guideline-recommended MRI sequences with the proposed slice orientation and slice thickness or voxel size. Additional sequences are used by 22 centers. MRI postprocessing methods are used in 16 centers. Interictal positron emission tomography (PET) is available in 22 centers; all using 18F-fluorodeoxyglucose (FDG). Seventeen centers perform PET postprocessing. Single-photon emission computed tomography (SPECT) is used by 19 centers, of which 15 perform postprocessing. Four centers perform neither PET nor SPECT in children. Seven centers apply magnetoencephalography (MEG) source localization, and nine apply electroencephalography (EEG) source localization. Fourteen combinations of inverse methods and volume conduction models are used. Significance: We report a large variation in the presurgical diagnostic workup among epilepsy surgery centers across Europe. This diversity underscores the need for highquality systematic reviews, evidence-based recommendations, and harmonization of available diagnostic presurgical methods.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicin0 (SwePub)3022 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicine0 (SwePub)3022 hsv//eng
653 a Epilepsy surgery
653 a Magnetic resonance imaging
653 a Single-photon emission computed tomography
653 a presurgical work-up
653 a phased-array mri
653 a clinical effectiveness
653 a cost-effectiveness
653 a ictal spect
653 a fdg-pet
653 a recommendations
653 a children
653 a magnetoencephalography
653 a guidelines
653 a Neurosciences & Neurology
700a Rados, M.4 aut
700a Barsi, P.4 aut
700a Boon, P.4 aut
700a Carmichael, D. W.4 aut
700a Carrette, E.4 aut
700a Craiu, D.4 aut
700a Cross, J. H.4 aut
700a Diehl, B.4 aut
700a Dimova, P.4 aut
700a Fabo, D.4 aut
700a Francione, S.4 aut
700a Gaskin, V.4 aut
700a Gil-Nagel, A.4 aut
700a Grigoreva, E.4 aut
700a Guekht, A.4 aut
700a Hirsch, E.4 aut
700a Hecimovic, H.4 aut
700a Helmstaedter, C.4 aut
700a Jung, J.4 aut
700a Kalviainen, R.4 aut
700a Kelemen, A.4 aut
700a Kimiskidis, V.4 aut
700a Kobulashvili, T.4 aut
700a Krsek, P.4 aut
700a Kuchukhidze, G.4 aut
700a Larsson, P. G.4 aut
700a Leitinger, M.4 aut
700a Lossius, M. I.4 aut
700a Luzin, R.4 aut
700a Malmgren, Kristina,d 1952u Gothenburg University,Göteborgs universitet,Institutionen för neurovetenskap och fysiologi, sektionen för klinisk neurovetenskap och rehabilitering,Institute of Neuroscience and Physiology, Department of Clinical Neuroscience and Rehabilitation4 aut0 (Swepub:gu)xmalkr
700a Mameniskiene, R.4 aut
700a Marusic, P.4 aut
700a Metin, B.4 aut
700a Ozkara, C.4 aut
700a Pecina, H.4 aut
700a Quesada, C. M.4 aut
700a Rugg-Gunn, F.4 aut
700a Rydenhag, Bertil,d 19544 aut
700a Ryvlin, P.4 aut
700a Scholly, J.4 aut
700a Seeck, M.4 aut
700a Staack, A. M.4 aut
700a Steinhoff, B. J.4 aut
700a Stepanov, V.4 aut
700a Tarta-Arsene, O.4 aut
700a Trinka, E.4 aut
700a Uzan, M.4 aut
700a Vogt, V. L.4 aut
700a Vos, S. B.4 aut
700a Vulliemoz, S.4 aut
700a Huiskamp, G.4 aut
700a Leijten, F. S. S.4 aut
700a Van Eijsden, P.4 aut
700a Braun, K. P. J.4 aut
710a Göteborgs universitetb Institutionen för neurovetenskap och fysiologi, sektionen för klinisk neurovetenskap och rehabilitering4 org
773t Epilepsiad : Wileyg 57:5, s. 770-776q 57:5<770-776x 0013-9580
856u https://onlinelibrary.wiley.com/doi/pdfdirect/10.1111/epi.13347
8564 8u https://gup.ub.gu.se/publication/242047
8564 8u https://doi.org/10.1111/epi.13347

Hitta via bibliotek

  • Epilepsia (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy