Altun, O.Karolinska Institutet
(författare)
Rapid identification of Streptococcus pneumoniae in blood cultures by using the ImmuLex, Slidex and Wellcogen latex agglutination tests and the BinaxNOW antigen test
- Artikel/kapitelEngelska2016
Förlag, utgivningsår, omfång ...
-
2016-01-21
-
Springer-Verlag New York,2016
-
printrdacarrier
Nummerbeteckningar
-
LIBRIS-ID:oai:DiVA.org:oru-49647
-
https://urn.kb.se/resolve?urn=urn:nbn:se:oru:diva-49647URI
-
https://doi.org/10.1007/s10096-015-2573-9DOI
-
http://kipublications.ki.se/Default.aspx?queryparsed=id:133298159URI
Kompletterande språkuppgifter
-
Språk:engelska
-
Sammanfattning på:engelska
Ingår i deldatabas
Klassifikation
-
Ämneskategori:ref swepub-contenttype
-
Ämneskategori:art swepub-publicationtype
Anmärkningar
-
Rapid identification of Streptococcus pneumoniae in blood culture (BC) bottles is important for early directed antimicrobial therapy in pneumococcal bacteraemia. We evaluated a new latex agglutination (LA) test on BC bottles, the ImmuLex™ S. pneumoniae Omni (Statens Serum Institut, Denmark), and compared the performance with the Slidex® pneumo-Kit (bioMérieux, France) and the Wellcogen™ S. pneumoniae (Remel, UK) LA tests, as well as the BinaxNOW® S. pneumoniae (Alere, USA) antigen test. The four tests were directly applied on 358 positive BC bottles with Gram-positive cocci in pairs or chains and on 15 negative bottles. Valid test results were recorded in all cases for ImmuLex and BinaxNOW and in 88.5 % (330/373) and 94.1 % (351/373) of cases for Slidex and Wellcogen, respectively. Based on bottles positive for S. pneumoniae by conventional methods, the sensitivity of ImmuLex was 99.6 %, similar to the other tests (range, 99.6-100 %). Based on bottles positive for non-pneumococcal pathogens, the specificity of ImmuLex was 82.6 %, in comparison to 97.6 % for Slidex (p < 0.01) and 85.4 % for Wellcogen (p = ns). The BinaxNOW test had a lower specificity (64.1 %) than any LA test (p < 0.01). On BC bottles positive for α-haemolytic streptococci, ImmuLex was positive in 12/67 (17.9 %) cases, Slidex in 2/59 (3.4 %) cases, Wellcogen in 11/64 (17.2 %) cases and BinaxNOW in 25/67 (37.3 %) cases. In conclusion, the ImmuLex test provides a valid and sensitive technique for the rapid detection of S. pneumoniae in BC bottles, similar to the other compared methods. However, the specificity was sub-optimal, since the test may cross-react with other Gram-positive bacteria.
Ämnesord och genrebeteckningar
Biuppslag (personer, institutioner, konferenser, titlar ...)
-
Athlin, Simon,1971-Örebro universitet,Institutionen för medicinska vetenskaper,Department of Infectious Diseases, Örebro University, Örebro, Sweden(Swepub:oru)soan
(författare)
-
Almuhayawi, M.Karolinska Institutet
(författare)
-
Strålin, K.Karolinska Institutet
(författare)
-
Özenci, V.Karolinska Institutet
(författare)
-
Karolinska InstitutetInstitutionen för medicinska vetenskaper
(creator_code:org_t)
Sammanhörande titlar
-
Ingår i:European Journal of Clinical Microbiology and Infectious Diseases: Springer-Verlag New York35:4, s. 579-5850934-97231435-4373
Internetlänk
Hitta via bibliotek
Till lärosätets databas