SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Önnby Linda)
 

Sökning: WFRF:(Önnby Linda) > Arsenic adsorption ...

  • Suresh, PrashanthLund University,Lunds universitet,Bioteknik,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biotechnology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH (författare)

Arsenic adsorption by iron-aluminium hydroxide coated onto macroporous supports : Insights from X-ray absorption spectroscopy and comparison with granular ferric hydroxides

  • Artikel/kapitelEngelska2016

Förlag, utgivningsår, omfång ...

  • Elsevier,2016
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:kth-180197
  • https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-180197URI
  • https://doi.org/10.1016/j.jhazmat.2015.09.065DOI
  • https://lup.lub.lu.se/record/8149112URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • QC 20160120
  • This paper evaluates the arsenic adsorption characteristics of a macroporous polymer coated with coprecipitated iron-aluminium hydroxides (MHCMP). The MHCMP adsorbent-composite fits best with a pseudo-second order model for As(III) and a pseudo-first order kinetic model for As(V). The MHCMP shows a maximum adsorption capacity of 82.3 and 49.6 mgAs/g adsorbent for As(III) and As(V) ions respectively, and adsorption followed the Langmuir model. Extended X-ray absorption fine structure showed that binding of As(III) ions were confirmed to take place on the iron hydroxides coated on the MHCMP, whereas for As(V) ions the binding specificity could not be attributed to one particular metal hydroxide. As(III) formed a bidentate mononuclear complex with Fe sites, whereas As(V) indicated on a bidentate binuclear complex with Al sites or monodentate with Fe sites on the adsorbent. The column experiments were run in a well water spiked with a low concentration of As(III) (100 mu g/L) and a commercially available adsorbent (GEH (R) 102) based on granular iron-hydroxide was used for comparison. It was found that the MHCMP was able to treat 7 times more volume of well water as compared to GEH (R) 102, maintaining the threshold concentration of less than 10 mu gAs/L, indicating that the MHCMP is a superior adsorbent.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Quiroga Flores, RoxanaLund University,Lunds universitet,Bioteknik,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biotechnology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH,Higher University of San Andrés(Swepub:lu)biot-raq (författare)
  • Sjöstedt, CarinKTH,Tillämpad fysikalisk kemi(Swepub:kth)u1t47q98 (författare)
  • Önnby, LindaLund University,Lunds universitet,Bioteknik,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biotechnology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH(Swepub:lu)biot-lno (författare)
  • BioteknikCentrum för tillämpade biovetenskaper (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Journal of Hazardous Materials: Elsevier302, s. 166-1740304-38941873-3336

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.