SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Henriksson Lilian)
 

Search: WFRF:(Henriksson Lilian) > The transluminal at...

The transluminal attenuation gradient does not add diagnostic accuracy to coronary computed tomography

Henriksson, Lilian (author)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Röntgenkliniken i Linköping
Woisetschläger, Mischa (author)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Region Östergötland, Röntgenkliniken i Linköping
Alfredsson, Joakim, 1962- (author)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Region Östergötland, Kardiologiska kliniken US
show more...
Janzon, Magnus, 1961- (author)
Linköpings universitet,Avdelningen för samhälle och hälsa,Medicinska fakulteten,Region Östergötland, Kardiologiska kliniken US
Ebbers, Tino (author)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV
Engvall, Jan, 1953- (author)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Fysiologiska kliniken US
Persson, Anders, 1953- (author)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Röntgenkliniken i Linköping
show less...
 (creator_code:org_t)
2020-07-28
2021
English.
In: Acta Radiologica. - : Sage Publications. - 0284-1851 .- 1600-0455. ; , s. 867-874
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Background A method for improving the accuracy of coronary computed tomography angiography (CCTA) is highly sought after as it would help to avoid unnecessary invasive coronary angiographies. Measurement of the transluminal attenuation gradient (TAG) has been proposed as an alternative to other existing methods, i.e. CT perfusion and CT fractional flow reserve (FFR). Purpose To evaluate the incremental value of three types of TAG in high-pitch spiral CCTA with invasive FFR measurements as reference. Material and Methods TAG was measured using two semi-automatic methods and one manual method. A receiver operating characteristic (ROC) analysis was made to determine the usefulness of TAG alone as well as TAG combined with CCTA for detection of significant coronary artery stenoses defined by an invasive FFR value <= 0.80. Results A total of 51 coronary vessels in 37 patients were included in this retrospective study. Hemodynamically significant stenoses were found in 13 vessels according to FFR. The ROC analysis TAG alone resulted in areas under the curve (AUCs) of 0.530 and 0.520 for the semi-automatic TAG and 0.557 for the manual TAG. TAG and CCTA combined resulted in AUCs of 0.567, 0.562 for semi-automatic TAG, and 0.569 for the manual TAG. Conclusion The results from our study showed no incremental value of TAG measured in single heartbeat CCTA in determining the severity of coronary artery stenosis degrees.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Keyword

Computed tomography angiography; coronary arteries; transluminal attenuation gradient; stenosis evaluation

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view