SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Pettersson Curt E)
 

Sökning: WFRF:(Pettersson Curt E) > Trace analysis of f...

Trace analysis of fluoxetine and its metabolite norfluoxetine : Part I: Development of a chiral liquid chromatography-tandem mass spectrometry method for wastewater samples

Barclay, Victoria K. H. (författare)
Uppsala universitet,Avdelningen för analytisk farmaceutisk kemi
Tyrefors, Niklas L. (författare)
Uppsala universitet,Avdelningen för analytisk farmaceutisk kemi
Johansson, I. Monika (författare)
Uppsala universitet,Avdelningen för analytisk farmaceutisk kemi
visa fler...
Pettersson, Curt E. (författare)
Uppsala universitet,Avdelningen för analytisk farmaceutisk kemi
visa färre...
 (creator_code:org_t)
Elsevier BV, 2011
2011
Engelska.
Ingår i: Journal of Chromatography A. - : Elsevier BV. - 0021-9673 .- 1873-3778. ; 1218:33, s. 5587-5596
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • An enantioselective method for the determination of fluoxetine (a selective serotonin reuptake inhibitor) and its pharmacologically active metabolite norfluoxetine has been developed for raw and treated wastewater samples. The stable isotope-labeled fluoxetine and norfluoxetine were used in an extended way for extraction recovery calculations at trace level concentrations in wastewater. Wastewater samples were enriched by solid phase extraction (SPE) with Evolute CX-50 extraction cartridges. The obtained extraction recoveries ranged between 65 and 82% in raw and treated wastewater at a trace level concentration of 50 pM (15-16 ng L(-1)). The target compounds were identified by the use of chiral liquid chromatography tandem mass spectrometry (LC-MS/MS) in selected reaction monitoring (SRM) mode. The enantiomers were successfully resolved on a chiral alpha(1)-acid glycoprotein column (chiral AGP) with acetonitrile and 10 mM ammonium acetate buffer at pH 4.4 (3/97, v/v) as the mobile phase. The effects of pH, amount of organic modifier and buffer concentration in the mobile phase were investigated on the enantiomeric resolution (R(s)) of the target compounds. Enantiomeric R(s)-values above 2.0 (1.03 RSD%, n = 3) were achieved for the enantiomers of fluoxetine and norfluoxetine in all mobile phases investigated. The method was validated by assessing parameters such as cross-contamination and carryover during SPE and during LC analysis. Cross-talk effects were examined during the detection of the analytes in SRM mode. In addition, the isotopic purity of fluoxetine-d(5) and norfluoxetine-d(5) were assessed to exclude the possibility of self-contamination. The interassay precision of the chromatographic separation was excellent, with relative standard deviations (RSD) equal to or lower than 0.56 and 0.81% in raw and treated wastewaters, respectively. The method detection and quantification limits (respectively, MDL and MQL) were determined by the use of fluoxetine-d5 and norfluoxetine-d5. The MQL for the single enantiomers ranged from 12 to 14 pM (3.6-4.3 ng L(-1)) in raw wastewater and from 3 to 4 pM (0.9-1 ng L(-1)) in treated wastewater. The developed method has been employed for the quantification of (R)-fluoxetine, (S)-fluoxetine and the enantiomers of norfluoxetine in raw and treated wastewater samples to be presented in Part II of this study.

Ämnesord

NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)

Nyckelord

Wastewater
Solid phase extraction
Fluoxetine
Norfluoxetine
Isotope-labeled compounds
Chiral LC-MS/MS
Chemistry
Kemi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Barclay, Victori ...
Tyrefors, Niklas ...
Johansson, I. Mo ...
Pettersson, Curt ...
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
Artiklar i publikationen
Journal of Chrom ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy