SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Anderson Mats)
 

Sökning: WFRF:(Anderson Mats) > Quartz crystal micr...

Quartz crystal microbalance sensor design : I. Experimental study of sensor response and performance

Anderson, Henrik (författare)
Uppsala universitet,Fasta tillståndets elektronik
Jönsson, Mats (författare)
Uppsala universitet,Fasta tillståndets elektronik
Vestling, Lars (författare)
Uppsala universitet,Fasta tillståndets elektronik
visa fler...
Lindberg, Ulf (författare)
Uppsala universitet,Fasta tillståndets elektronik
Aastrup, Teodor (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2007
2007
Engelska.
Ingår i: Sensors and actuators. B, Chemical. - : Elsevier BV. - 0925-4005 .- 1873-3077. ; 123:1, s. 27-34
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This paper investigates a novel quartz crystal microbalance (QCM) biosensor with a small and rectangular flow cell along with a correspondingly shaped crystal electrode. The sensor was evaluated with impedance analysis and compared to standard circular sensor crystals and sensor crystals with small circular electrodes. Comparative QCM measurements on an antibody–antigen interaction system were carried out on the rectangular and standard circular sensor systems. Impedance analysis and subsequent data extraction of the three different sensor crystals showed that the smaller sensors had significantly higher Q-values in air, but that liquid load on the electrodes lowered the Q-values radically for all crystals. Under liquid load, Q-values for the standard circular and the rectangular sensors were similar whereas the Q-value for the small circular sensor was 50% higher. QCM experiments showed that the QCM system with rectangular crystal electrodes was fully functional in a liquid environment. The rectangular system showed higher and more rapid responses for series of antibody injections, albeit at a higher noise level than the standard system. The study elucidates a significant potential for improvement of sensor performance by optimising the sensor electrode size and shape together with the flow cell geometry.

Nyckelord

QCM
Biosensor
Sensitivity
Mass transport
Protein interactions
TECHNOLOGY
TEKNIKVETENSKAP

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy