Sökning: WFRF:(Tomic Hanna) > Development and eva...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 06897naa a2200433 4500 | |
001 | oai:lup.lub.lu.se:323196bb-3eb4-4488-bccb-97d35d84f9a8 | |
003 | SwePub | |
008 | 220927s2022 | |||||||||||000 ||eng| | |
024 | 7 | a https://lup.lub.lu.se/record/323196bb-3eb4-4488-bccb-97d35d84f9a82 URI |
024 | 7 | a https://doi.org/10.1117/1.JMI.9.3.0335032 DOI |
040 | a (SwePub)lu | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a art2 swepub-publicationtype |
072 | 7 | a ref2 swepub-contenttype |
100 | 1 | a Tomic, Hannau Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Medicinsk strålningsfysik, Malmö,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Radiology Diagnostics, Malmö,Lund University Research Groups,Medical Radiation Physics, Malmö,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital4 aut0 (Swepub:lu)ha8665to |
245 | 1 0 | a Development and evaluation of a method for tumor growth simulation in virtual clinical trials of breast cancer screening |
264 | 1 | c 2022 |
520 | a Purpose: Image-based analysis of breast tumor growth rate may optimize breast cancer screening and diagnosis by suggesting optimal screening intervals and guide the clinical discussion regarding personalized screening based on tumor aggressiveness. Simulation-based virtual clinical trials (VCTs) can be used to evaluate and optimize medical imaging systems and design clinical trials. This study aimed to simulate tumor growth over multiple screening rounds. Approach: This study evaluates a preliminary method for simulating tumor growth. Clinical data on tumor volume doubling time (TVDT) was used to fit a probability distribution ("clinical fit") of TVDTs. Simulated tumors with TVDTs sampled from the clinical fit were inserted into 30 virtual breasts ("simulated cohort") and used to simulate mammograms. Based on the TVDT, two successive screening rounds were simulated for each virtual breast. TVDTs from clinical and simulated mammograms were compared. Tumor sizes in the simulated mammograms were measured by a radiologist in three repeated sessions to estimate TVDT. Results: The mean TVDT was 297 days (standard deviation, SD, 169 days) in the clinical fit and 322 days (SD, 217 days) in the simulated cohort. The mean estimated TVDT was 340 days (SD, 287 days). No significant difference was found between the estimated TVDTs from simulated mammograms and clinical TVDT values (p > 0.5). No significant difference (p > 0.05) was observed in the reproducibility of the tumor size measurements between the two screening rounds. Conclusions: The proposed method for tumor growth simulation has demonstrated close agreement with clinical results, supporting potential use in VCTs of temporal breast imaging. | |
650 | 7 | a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe |
650 | 7 | a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng |
653 | a digital mammography | |
653 | a simulation | |
653 | a tumor growth | |
653 | a tumor volume doubling time | |
653 | a virtual clinical trials | |
700 | 1 | a Bjerkén, Annau Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Medical Radiation Physics, Malmö,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital4 aut0 (Swepub:lu)an5554be |
700 | 1 | a Hellgren, Gustavu Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups,Skåne University Hospital4 aut0 (Swepub:lu)gu3840he |
700 | 1 | a Johnson, Kristinu Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Radiology Diagnostics, Malmö,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital4 aut0 (Swepub:lu)kr6867jo |
700 | 1 | a Förnvik, Danielu Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Medical Radiation Physics, Malmö,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital4 aut0 (Swepub:lu)med-dif |
700 | 1 | a Zackrisson, Sophiau Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,LTH profilområde: Avancerade ljuskällor,LTH profilområden,Lunds Tekniska Högskola,Radiology Diagnostics, Malmö,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments,LTH Profile Area: Photon Science and Technology,LTH Profile areas,Faculty of Engineering, LTH,Skåne University Hospital4 aut0 (Swepub:lu)smi-sza |
700 | 1 | a Tingberg, Andersu Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Medical Radiation Physics, Malmö,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital4 aut0 (Swepub:lu)rfa-ati |
700 | 1 | a Dustler, Magnusu Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Medicinsk strålningsfysik, Malmö,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Radiology Diagnostics, Malmö,Lund University Research Groups,Medical Radiation Physics, Malmö,LUCC: Lund University Cancer Centre,Other Strong Research Environments4 aut0 (Swepub:lu)med-mdu |
700 | 1 | a Bakic, Predrag R.u Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Radiology Diagnostics, Malmö,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Hospital of the University of Pennsylvania4 aut0 (Swepub:lu)pr1633ba |
710 | 2 | a Diagnostisk radiologi, Malmöb Forskargrupper vid Lunds universitet4 org |
773 | 0 | t Journal of Medical Imagingg 9:3q 9:3x 2329-4302 |
856 | 4 | u http://dx.doi.org/10.1117/1.JMI.9.3.033503x freey FULLTEXT |
856 | 4 8 | u https://lup.lub.lu.se/record/323196bb-3eb4-4488-bccb-97d35d84f9a8 |
856 | 4 8 | u https://doi.org/10.1117/1.JMI.9.3.033503 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.