SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Vorontsova O)
 

Sökning: WFRF:(Vorontsova O) > Measuring Uptake an...

Measuring Uptake and Elimination of Nitrogen in Humans at Different Ambient Pressures

Sundblad, Patrik (författare)
Karolinska Institutet,KTH,Omgivningsfysiologi,Centrum för flyg- och rymdfysiologi, SAPC,KTH, SWE
Franberg, Oskar (författare)
Blekinge Tekniska Högskola,Institutionen för maskinteknik
Siebenmann, Christoph (författare)
KTH,Omgivningsfysiologi,Centrum för flyg- och rymdfysiologi, SAPC,KTH, SWE
visa fler...
Gennser, Mikael (författare)
KTH,Omgivningsfysiologi,Centrum för flyg- och rymdfysiologi, SAPC,KTH, SWE
visa färre...
 (creator_code:org_t)
AEROSPACE MEDICAL ASSOC, 2016
2016
Engelska.
Ingår i: Aerospace Medicine and Human Performance. - : AEROSPACE MEDICAL ASSOC. - 2375-6314. ; 87:12, s. 1045-1050
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: To measure nitrogen (N-2) wash-out and uptake requires elaborate set-ups, especially when doing the measurements at increased or decreased ambient pressure. Here we present a transportable device for quantifying N-2 turnover in humans which can be used at different ambient pressures. METHODS: A modified close-circuit electronic rebreather was used to assess N-2 turnover. Changes in N-2 volume within the rebreathing circuit, reflecting N-2 uptake or washout, were derived from the continuously monitored total system volume and the calculated volumes of oxygen and water vapor. The calculation of continuous N-2 volume curves was performed off-line using dedicated computer software. RESULTS: Four subjects participated in the proof-of-concept tests. At steady state, the drift in calculated N-2 volume in the rebreathing circuit over a 1-h duration was minimal. Three of the subjects participated in additional N-2 steady-state measurements where 1019 mL (BTPD) of N-2 was injected into the rebreathing circuit over 20 min and the measured volume increase was 1006 +/- 32 mL. Lastly, N-2 elimination was assessed during decompression to 0.5 atm and while breathing hyperoxic gas. N-2 uptake was measured during compression to 1.8 atm. The elimination and uptake curves were deemed to be realistic. DISCUSSION: A method for assessing N-2 turnover in humans has been developed and a first evaluation has been performed. It is easy to work with operationally and can be used at different ambient pressures. More research is needed in order to further validate it as a method for assessing N-2 turnover in humans.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)

Nyckelord

decompression
nitrogen elimination
pressure
diving

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy