SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Digas Georgios 1963)
 

Sökning: WFRF:(Digas Georgios 1963) > New polymer materia...

New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters

Digas, Georgios, 1963 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för ortopedi,Institute of Surgical Sciences, Department of Orthopaedics
 (creator_code:org_t)
2005
2005
Engelska.
Ingår i: Acta Orthop Suppl. - 1745-3690. ; 76:315, s. 3-82
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • AIMS: To evaluate the outcome of different types of polyethylene, bone cements and one design of uncemented fixation with porous and ceramic coating using radiostereometry, bone densitometry, conventional radiography and clinical parameters. MATERIALS AND METHODS: Study I: 201 patients were extracted from 5 prospective randomised studies to evaluate femoral head penetration at two years with radiostereometry in four basic designs, cemented Lubinus and Reflection cups, uncemented Trilogy and Reflection cups. Studies II and III: 60 patients (61 hips) were randomised to receive either highly cross-linked or conventional all PE cups. 32 patients with bilateral arthrosis received hybrid THA with highly cross-linked PE on one side and conventional on the contra lateral side. Femoral head penetration and the migration of the cups were evaluated with radiostereometry in the supine and standing positions. DEXA and conventional radiography were used to evaluate the bone mineral density and radiolucencies around the cemented acetabular component. Studies IV and V: 90 patients (97 and 96 hips respectively) were stratified depended on age, gender, diagnosis and preoperative BMD to create 3 main groups of socket fixation. In the first group fluoride containing cement was used, in the second group Palacos cum Gentamicin and in the third hybrid THA with porous coated HA/TCP cup. In the hybrid group the fixation of the femoral component was again randomised to either of the two cements. The results on femoral and acetabular sides are presented separately in studies IV and V, respectively. RESULTS: Study I: Cups with polyethylene sterilized in EtO had almost twice the proximal and 3D penetration rates compared with gamma-sterilized polyethylene. Regression analysis showed that the type of sterilization, age and weight was the most important factors affecting the penetration rate. Studies II and III: In the cemented study the proximal penetration was lower in the study group independent of position at 3 years, while in the hybrid study the penetration was lower in the study group only in the supine position at 2 years. The migration of the cup did not differ between the plastics in both studies. At 2 years the periprosthetic radiolucency and BMD did not differ significantly between the 2 types of PE used in the cemented study. Study IV: The subsidence of the stem did not differ between the groups, but the periprosthetic BMD decreased more in fluoride cement group at 2 years. Conventional radiography revealed higher progression of radiolucent lines in the Palacos group, but only in one region. Study V: The proximal migration of the cup was almost similar in all three groups. The three dimensional migration was increased in patients with osteoporosis. Postoperative radiolucent lines tended to disappear with use of porous coating covered with HA/TCP. CONCLUSIONS: Study I: EtO sterilized polyethylene increased the femoral head penetration. Age and weight were also important predictors of the penetration rate. Studies II and III: The highly cross-linked polyethylene decreased the penetration rate mainly after one year probably reflecting less wear. The different mechanical properties of the two types of PE studied did not affect the early fixation of the cemented cup. Study IV: There were no obvious advantage of addition of fluoride to acrylic bone cement when used to fixate the femoral component. Study V: Use of fluoride containing cement or uncemented fixation did not improve the early stability of the socket compared to Palacos with Gentamicin.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

Arthroplasty
Replacement
Hip/adverse effects/methods
*Bone Cements
Bone Density/physiology
Cementation
*Compressive Strength
Densitometry
X-Ray/methods
Equipment Failure Analysis/*methods
Female
*Hip Prosthesis/adverse effects
Humans
Joint Instability/etiology/*prevention & control
Male
Materials Testing/*methods
Osseointegration/physiology
Polyethylenes/*pharmacology
Prognosis
Prosthesis Design
Prosthesis Failure
Range of Motion
Articular/physiology
Recovery of Function
Risk Assessment
Stress
Mechanical
Treatment Outcome

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Digas, Georgios, ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
Artiklar i publikationen
Acta Orthop Supp ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy