Sökning: L773:0169 2607 > A graphic user inte...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 02995naa a2200433 4500 | |
001 | oai:DiVA.org:su-51752 | |
003 | SwePub | |
008 | 110112s2010 | |||||||||||000 ||eng| | |
009 | oai:prod.swepub.kib.ki.se:121371380 | |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:su:diva-517522 URI |
024 | 7 | a https://doi.org/10.1016/j.cmpb.2010.02.0032 DOI |
024 | 7 | a http://kipublications.ki.se/Default.aspx?queryparsed=id:1213713802 URI |
040 | a (SwePub)sud (SwePub)ki | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a Su, Fan-Chi4 aut |
245 | 1 0 | a A graphic user interface toolkit for specification, report and comparison of dose-response relations and treatment plans using the biologically effective uniform dose |
264 | 1 | b Elsevier BV,c 2010 |
338 | a print2 rdacarrier | |
500 | a authorCount :5 | |
520 | a A toolkit (BEUDcal) has been developed for evaluating the effectiveness and for predicting the outcome of treatment plans by calculating the biologically effective uniform dose (BEUD) and complication-free tumor control probability. The input for the BEUDcal is the differential dose-volume histograms of organs exported from the treatment planning system. A clinical database is built for the dose-response parameters of different tumors and normal tissues. Dose-response probabilities of all the examined organs are illustrated together with the corresponding BEUDs and the P+ values. Furthermore, BEUDcal is able to generate a report that simultaneously presents the radiobiological evaluation together with the physical dose indices, showing the complementary relation between the physical and radiobiological treatment plan analysis performed by BEUDcal. Comparisons between treatment plans for helical tomotherapy and multileaf collimator-based intensity modulated radiotherapy of a lung patient were demonstrated to show the versatility of BEUDcal in the assessment and report of dose-response relations. | |
653 | a Biologically effective uniform dose | |
653 | a Helical tomotherapy | |
653 | a Treatment planning | |
653 | a Radiobiological objectives | |
653 | a NATURAL SCIENCES | |
653 | a NATURVETENSKAP | |
700 | 1 | a Mavroidis, Panayiotisu Karolinska Institutet,Stockholms universitet,Medicinsk strålningsfysik (tills m KI)4 aut |
700 | 1 | a Shi, Chengyu4 aut |
700 | 1 | a Ferreira, Brigida Costa4 aut |
700 | 1 | a Papanikolaou, Niko4 aut |
710 | 2 | a Stockholms universitetb Medicinsk strålningsfysik (tills m KI)4 org |
773 | 0 | t Computer Methods and Programs in Biomedicined : Elsevier BVg 100:1, s. 69-78q 100:1<69-78x 0169-2607x 1872-7565 |
856 | 4 | u https://europepmc.org/articles/pmc2929303?pdf=render |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:su:diva-51752 |
856 | 4 8 | u https://doi.org/10.1016/j.cmpb.2010.02.003 |
856 | 4 8 | u http://kipublications.ki.se/Default.aspx?queryparsed=id:121371380 |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.