SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:8206a127-a245-4b6b-ae77-1c1959456628"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:8206a127-a245-4b6b-ae77-1c1959456628" > AAPM task group rep...

AAPM task group report 302 : Surface-guided radiotherapy

Al-Hallaq, Hania A. (författare)
University of Chicago
Cerviño, Laura (författare)
Memorial Sloan-Kettering Cancer Center
Gutierrez, Alonso N. (författare)
Miami Cancer Institute at Baptist Health South Florida
visa fler...
Havnen-Smith, Amanda (författare)
Mayo Clinic Minnesota
Higgins, Susan A. (författare)
Yale University
Kügele, Malin (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Radiotherapy Physics,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Lund University Research Groups,Skåne University Hospital
Padilla, Laura (författare)
University of California, San Diego
Pawlicki, Todd (författare)
University of California, San Diego
Remmes, Nicholas (författare)
Mayo Clinic Minnesota
Smith, Koren (författare)
University of California, San Diego
Tang, Xiaoli (författare)
University of California, San Diego
Tomé, Wolfgang A. (författare)
Yeshiva University
visa färre...
 (creator_code:org_t)
2022-03-15
2022
Engelska 88 s.
Ingår i: Medical Physics. - : Wiley. - 0094-2405 .- 2473-4209. ; 49:4, s. 82-112
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The clinical use of surface imaging has increased dramatically, with demonstrated utility for initial patient positioning, real-time motion monitoring, and beam gating in a variety of anatomical sites. The Therapy Physics Subcommittee and the Imaging for Treatment Verification Working Group of the American Association of Physicists in Medicine commissioned Task Group 302 to review the current clinical uses of surface imaging and emerging clinical applications. The specific charge of this task group was to provide technical guidelines for clinical indications of use for general positioning, breast deep-inspiration breath hold treatment, and frameless stereotactic radiosurgery. Additionally, the task group was charged with providing commissioning and on-going quality assurance (QA) requirements for surface-guided radiation therapy (SGRT) as part of a comprehensive QA program including risk assessment. Workflow considerations for other anatomic sites and for computed tomography simulation, including motion management, are also discussed. Finally, developing clinical applications, such as stereotactic body radiotherapy (SBRT) or proton radiotherapy, are presented. The recommendations made in this report, which are summarized at the end of the report, are applicable to all video-based SGRT systems available at the time of writing.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Nyckelord

deep inspiration breath hold
frameless radiosurgery
risk assessment
surface guided radiotherapy

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy