SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:prod.swepub.kib.ki.se:146466907"
 

Sökning: onr:"swepub:oai:prod.swepub.kib.ki.se:146466907" > eCLIPs bifurcation ...

eCLIPs bifurcation remodeling system for treatment of wide neck bifurcation aneurysms with extremely low dome-to-neck and aspect ratios: a multicenter experience

De Vries, J (författare)
Boogaarts, HD (författare)
Sorensen, L (författare)
visa fler...
Holtmannspoetter, M (författare)
Benndorf, G (författare)
Turowski, B (författare)
Bohner, G (författare)
Derakhshani, S (författare)
Navasa, C (författare)
van Zwam, WH (författare)
Soderman, M (författare)
Karolinska Institutet
Rautio, R (författare)
Mathys, C (författare)
Riina, H (författare)
Marotta, TR (författare)
visa färre...
 (creator_code:org_t)
2020-08-11
2021
Engelska.
Ingår i: Journal of neurointerventional surgery. - : BMJ. - 1759-8486 .- 1759-8478. ; 13:5, s. 438-
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Wide necked bifurcation aneurysms (WNBA) are among the most difficult aneurysms to treat. Very low dome-to-neck (DTN) and aspect ratios provide an even greater challenge in the management of WNBAs. We present the safety and efficacy profile for endovascular clip system (eCLIPs) device in the treatment of this subset of WNBAs with very unfavorable morphologies.MethodsIn our case series, 24 patients treated at 12 international centers were taken from a larger prospective voluntary post-marketing registry of 65 patients treated with the eCLIPs device and coiling. Those who had WNBAs at either the carotid or basilar terminus with a DTN ratio <1.6 and aspect ratio <1.2 were included. Radiologic and clinical outcomes were assessed immediately after the procedure and at the latest follow-up.ResultsThe eCLIPs device was successfully deployed in 23 cases (96%). One patient (4.2%) died due to guidewire perforation distal to the implant site. No other complications were documented. After a mean follow-up of 15.8 months (range 3–40 months), good radiologic outcomes (modified Raymond–Roy classification (MRRC) scores of 1 or 2) were documented in 20 of 21 patients (95%) with follow-up data. The lone patient with an MRRC score of 3 showed coiled compaction after incomplete neck coverage with the device.ConclusionOur series of patients with aneurysms having adverse DTN and aspect ratios demonstrated that the eCLIPs device has a safety and efficacy profile comparable with currently available devices in the treatment of WNBAs.

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy