SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:miun-36195"
 

Sökning: onr:"swepub:oai:DiVA.org:miun-36195" > I-BAND-GEM :

I-BAND-GEM : a new way for improving BAND-GEM efficiency to thermal and cold neutrons

Croci, Gabriele (författare)
Univ Milano Bicocca, Milan, Italy
Muraro, Andrea (författare)
CNR, Milan, Italy
Cippo, Enrico Perelli (författare)
CNR, Milan, Italy
visa fler...
Grosso, Giovanni (författare)
CNR, Milan, Italy
Hoglund, Carina (författare)
European Spallat Source ESS AB, Lund
Hall-Wilton, Richard (författare)
Mittuniversitetet,Institutionen för elektronikkonstruktion,European Spallat Source ESS AB, Lund
Murtas, Fabrizio (författare)
Ist Nazl Fis Nucl, Frascati, Italy
Raspino, Davide (författare)
Rutherford Appleton Lab, Didcot, Oxon, England
Robinson, Linda (författare)
European Spallat Source ESS AB, Lund
Rhodes, Nigel (författare)
Rutherford Appleton Lab, Didcot, Oxon, England
Rebai, Marica (författare)
CNR, Milan, Italy
Schooneveld, Erik (författare)
Rutherford Appleton Lab, Didcot, Oxon, England
Defendi, Ilario (författare)
TUM, Garching, Germany
Zeitelhack, Karl (författare)
TUM, Garching, Germany
Tardocchi, Marco (författare)
CNR, Milan, Italy
Gorini, Giuseppe (författare)
Univ Milano Bicocca, Milan, Italy
visa färre...
 (creator_code:org_t)
2019-04-19
2019
Engelska.
Ingår i: The European Physical Journal Plus. - : Springer Science and Business Media LLC. - 2190-5444. ; 134:4
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • .The BAND-GEM detector represents one of the novel thermal neutron detection devices that have been developed in order to fulfil the needs of high intensity neutron sources that, like ESS (the European Spallation Source), will start operation in the next few years. The first version of this detector featured a detection efficiency of about 40% for neutrons with a wavelength of 4 angstrom, a spatial resolution of about 6mm and a rate capability in the order of some MHz/cm(2). The novelty of this device is represented by an improved 3D converter cathode (10 cm thick) based on (B4C)-B-10-coated aluminum grids positioned in a controlled gas mixture volume put on top of a Triple GEM amplifying stage. The position where the neutron interacts in the converter depends on their energy and it was observed that the first version of the detector would suffer from an efficiency decrease for long (>5 angstrom) neutron wavelength. This paper describes how the new 3D cathode allowed improving the detection efficiency at long neutron wavelengths while keeping all the benefits of the first BAND-GEM version.

Ämnesord

NATURVETENSKAP  -- Fysik -- Acceleratorfysik och instrumentering (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Accelerator Physics and Instrumentation (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy