SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-189337"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-189337" > Double-GEM based th...

Double-GEM based thermal neutron detector prototype

Serra Filho, L. A. (författare)
Univ Sao Paulo, Brazil
dos Santos, R. Felix (författare)
Univ Sao Paulo, Brazil
de Souza, G. G. A. (författare)
Univ Sao Paulo, Brazil
visa fler...
Paulino, M. M. M. (författare)
Univ Sao Paulo, Brazil
Souza, F. A. (författare)
Inst Pesquisas Energet & Nucl, Brazil
Moralles, M. (författare)
Inst Pesquisas Energet & Nucl, Brazil
da Luz, H. N. (författare)
Czech Tech Univ, Czech Republic
Bregant, M. (författare)
Univ Sao Paulo, Brazil
Munhoz, M. G. (författare)
Univ Sao Paulo, Brazil
Lai, Chung-Chuan (författare)
Linköpings universitet,Tunnfilmsfysik,Tekniska fakulteten,European Spallat Source ERIC ESS, Sweden
Hoglund, C. (författare)
European Spallat Source ERIC ESS, Sweden; Impact Coatings AB, Westmansgatan 29G, S-58216 Linkoping, Sweden
Svensson, P-O (författare)
European Spallat Source ERIC ESS, Sweden
Robinson, L. (författare)
European Spallat Source ERIC ESS, Sweden
Hall-Wilton, R. (författare)
European Spallat Source ERIC ESS, Sweden; Univ Milano Bicocca, Italy
visa färre...
 (creator_code:org_t)
IOP Publishing Ltd, 2022
2022
Engelska.
Ingår i: Journal of Instrumentation. - : IOP Publishing Ltd. - 1748-0221 .- 1748-0221. ; 17:9
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The Helium-3 shortage and the growing interest in neutron science constitute a driving factor in developing new neutron detection technologies. In this work, we report the development of a double-GEM detector prototype that uses a (B4C)-B-10 layer as a neutron converter material. GEANT4 simulations were performed predicting an efficiency of (3.14 +/- 0.10)%, agreeing within 2.7 sigma with the experimental and analytic detection efficiencies obtained by the detector when tested in a 41.8 meV thermal neutron beam. The detector is position sensitive, equipped with a 256+256 strip readout connected to resistive chains, and achieves a spatial resolution better than 3 mm. The gain stability over time was also measured with a fluctuation of about 0.2% h(-1) of the signal amplitude. A simple data acquisition with only 5 electronic channels is sufficient to operate this detector.

Ämnesord

NATURVETENSKAP  -- Fysik -- Acceleratorfysik och instrumentering (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Accelerator Physics and Instrumentation (hsv//eng)

Nyckelord

Neutron detectors (cold
thermal
fast neutrons); Micropattern gaseous detectors (MSGC
GEM
THGEM
RETHGEM
MHSP
MICROPIC
MICROMEGAS
InGrid
etc); Gaseous detectors

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy