Single Photon Emission Computed Tomography (SPECT) and SPECT/CT Hybrid Imaging

Ljungberg, Michael (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Nuclear Medicine Physics,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Lund University Research Groups
Erlandsson, Kjell (författare)
University College London
Ljungberg, Michael (redaktör/utgivare)
 (creator_code:org_t)
1
2022
2022
Engelska 17 s.
Ingår i: Handbook of Nuclear Medicine and Molecular Imaging for Physicists : Instrumentation and Imaging Procedures - Instrumentation and Imaging Procedures. - 9781138593268 - 9780429489556 ; 1
  • Bokkapitel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Images created using a standard collimator-based scintillation camera are essentially 2D images, lacking information regarding the source depth, since the value in a particular pixel in the image represents detection of photons along a line determined by the collimator. However, it is possible to reconstruct a set of 2D images that together form a 3D image of the underlying activity distribution from data acquired of the same source distribution at different projection angles around the object. This chapter will describe the way in which these data can be used to reconstruct transversal images by the filtered back-projection (FBP) method as well as by iterative algorithms, and also how noise regularization can be implemented. Various physical factors that affect the reconstructed images will also be discussed. If we combine a SPECT system with a CT system and display the images from both as a single hybrid image, additional useful information can be obtained. The CT information can also be used to correct for non-homogeneous attenuation, scatter, and partial-volume effects. Finally, the chapter will discuss how the combination of quantitative SPECT images registered to CT images can be used for dosimetry calculations.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

kap (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ljungberg, Micha ...
Erlandsson, Kjel ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Handbook of Nucl ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy