SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:87a83c41-9e88-4c64-84bd-828c7276efec"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:87a83c41-9e88-4c64-84bd-828c7276efec" > Perfusion assessmen...

Perfusion assessment with bolus differentiation : a technique applicable to hyperpolarized tracers

Johansson, Edvin (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
Olsson, L E (författare)
Amersham Health R and D, Malmö
Månsson, S (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups,Skåne University Hospital
visa fler...
Petersson, J S (författare)
Amersham Health R and D, Malmö
Golman, K (författare)
Lund University,Lunds universitet,Handkirurgi, Malmö,Forskargrupper vid Lunds universitet,Diagnostisk radiologi, Malmö,Hand Surgery, Malmö,Lund University Research Groups,Radiology Diagnostics, Malmö
Ståhlberg, F (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medicinsk strålningsfysik, Lund,Institutionen för kliniska vetenskaper, Lund,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Medical Radiation Physics, Lund,Department of Clinical Sciences, Lund
Wirestam, R (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Ceberg, Sofie (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
visa färre...
 (creator_code:org_t)
2004-10-26
2004
Engelska 9 s.
Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 0740-3194 .- 1522-2594. ; 52:5, s. 51-1043
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A new technique for assessing tissue blood flow using hyperpolarized tracers, based on the fact that the magnetization of a hyperpolarized substance can be destroyed permanently, is described. Assessments of blood flow with this technique are inherently insensitive to arterial delay and dispersion, and allow for quantification of the transit time and dispersion in the arteries that supply the investigated tissue. Renal cortical blood flow was studied in six rabbits using a 13C-labeled compound (2-hydroxyethylacrylate) that was polarized by the parahydrogen-induced polarization (PHIP) technique. The renal cortical blood flow was estimated to be 5.7/5.4 +/- 1.6/1.3 ml/min per milliliter of tissue (mean +/- SD, right/left kidney), and the mean transit time and dispersion in the renal arteries were determined to be 1.47/1.42 +/- 0.07/0.07 s and 1.78/1.93 +/- 0.40/0.42 s2, respectively.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Algorithms
Animals
Artifacts
Blood Volume
Carbon Isotopes
Image Processing, Computer-Assisted
Magnetic Resonance Imaging
Male
Rabbits
Renal Circulation
Statistics, Nonparametric

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy