A simple and fast liquid-liquid extraction method for the determination of 2,2 ',4,4 ',5,5 '-hexachlorobiphenyl (CB-153) and 1,1-dichloro-2,2-bis(p-chlorophenyl)-ethylene (p,p '-DDE) from human serum for epidemiological studies on type 2 diabetes

Rantakokko, Panu (författare)
Kiviranta, Hannu (författare)
Rylander, Lars (författare)
Lund University,Lunds universitet,Avdelningen för arbets- och miljömedicin,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Occupational and Environmental Medicine, Lund University,Department of Laboratory Medicine,Faculty of Medicine
visa fler...
Rignell-Hydbom, Anna (författare)
Lund University,Lunds universitet,Avdelningen för arbets- och miljömedicin,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Occupational and Environmental Medicine, Lund University,Department of Laboratory Medicine,Faculty of Medicine
Vartiainen, Terttu (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2009
2009
Engelska.
Ingår i: Journal of Chromatography A. - : Elsevier BV. - 0021-9673. ; 1216:6, s. 897-901
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A simple and fast method is presented to be used for example in studies on the relationship between serum levels of persistent organic pollutants and type 2 diabetes mellitus. Method is based on liquid-liquid extraction and gas chromatography coupled with high.-resolution mass spectrometry. In the sample pretreatment special attention was paid to minimize the number of sample manipulation steps and the amounts of organic solvents needed. Compounds analyzed were 2,2',4,4',5,5'-hexachlorobiphenyl (PCB-153) and 1,1-dichloro-2,2-bis (p-chlorophenyl)-ethylene (p,p'-DDE), the major metabolite of DDT. The method included extraction and cleanup of 0.2 rill of serum in a single test tube and subsequent analysis of the extract from 0.2 ml final volume. Validation was conducted to explore the performance of the method. The limits of detection for p,p'-DDE and PCB-153 based on the standard deviation of the blank samples were 4.3 and 3.1 pg/ml, respectively. Repeatability was less than 2.5% at three concentration levels tested and recovery from Certified Reference Material SRM 1589a was 84% for p,p'-DDE and 87% for PCB-153 of the certified values, respectively. Serum samples from the AMAP intercalibration round 2008-2 were also analyzed, and results were 101-116% of the assigned values. The presented method was used for an epidemiological study with more than 700 serum samples from a type 2 diabetes cohort from Sweden. (C) 2008 Elsevier B.V. All rights reserved.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Arbetsmedicin och miljömedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Occupational Health and Environmental Health (hsv//eng)

Nyckelord

PCB-153
p
p '-DDE
organic pollutants (POPs)
Persistent
Type 2 diabetes
Liquid-liquid extraction
Human serum

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy