SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:kau-21457"
 

Sökning: id:"swepub:oai:DiVA.org:kau-21457" > Microextraction in ...

Microextraction in Packed Syringe Online with Liquid Chromatography-Tandem Mass Spectrometry : Molecularly imprinted polymer as packing material for MEPS in selective extraction of ropivacaine from plasma

Abdel-Rehim, Mohamed (författare)
AstraZeneca R&D Södertälje, Södertälje, Sweden
Andersson, L.I. (författare)
AstraZeneca R&D Södertälje, Södertälje, Sweden
Altun, Zeki (författare)
Karlstads universitet,Avdelningen för kemi och biomedicinsk vetenskap
visa fler...
Blomberg, Lars G (författare)
Karlstads universitet,Avdelningen för kemi och biomedicinsk vetenskap
visa färre...
 (creator_code:org_t)
2007-02-07
2006
Engelska.
Ingår i: Journal of Liquid Chromatography & Related Technologies. - : Informa UK Limited. - 1082-6076 .- 1520-572X. ; 29:12, s. 1725-1736
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The excellent performance of a new sample preparation method, microextraction in packed syringe (MEPS), was recently illustrated by online LC‐MS and GS‐MS assays of local anaesthetics in plasma samples. In the method, approximately 1 mg of solid packing material was inserted into a syringe (100–250 µL) as a plug. Sample preparation took place on the packed bed. The new method was easy to use, fully automated, of low cost, and rapid in comparison with previously used methods. This paper presents the use of molecularly imprinted polymers (MIPs) as packing material for higher extraction selectivity. Development and validation of a method for MIP‐MEPS online with LC‐MS‐MS using ropivacaine in plasma as model compound were investigated. A bupivacaine imprinted polymer was used. The method was validated and the standard curves were evaluated by means of quadratic regression and weighted by inverse of the concentration: 1/x for the calibration range 2–2000 nM. The applied polymer could be used more than 100 times before the syringe was discarded. The extraction recovery was 60%. The results showed high correlation coefficients (R 2 >0.999) for all runs. The accuracy, given as a percentage deviation from the nominal concentration values, ranged from -6% to 3%. The precision, given as the relative standard deviation, at three different concentrations (QC samples) was consistently about 3% to 10%. The limit of quantification was 2 nM.

Ämnesord

NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)

Nyckelord

Column liquid chromatography‐tandem mass spectrometry
Column liquid chromatography-tandem mass spectrometry
Molecularly imprinted polymers
Ropivacaine
Sample preparation
Chemistry
Kemi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Abdel-Rehim, Moh ...
Andersson, L.I.
Altun, Zeki
Blomberg, Lars G
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
Artiklar i publikationen
Journal of Liqui ...
Av lärosätet
Karlstads universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy