Development of a Timepix based detector for the NanoXCT project

Nachtrab, F. (författare)
Fraunhofer Development Center X-ray Technology EZRT, Fürth, Germany
Hofmann, T. (författare)
Fraunhofer Development Center X-ray Technology EZRT, Fürth, Germany
Speier, C. (författare)
Fraunhofer Development Center X-ray Technology EZRT, Fürth, Germany
visa fler...
Lucic, J. (författare)
Fraunhofer Development Center X-ray Technology EZRT, Fürth, Germany
Firsching, M. (författare)
Fraunhofer Development Center X-ray Technology EZRT, Fürth, Germany
Uhlmann, N. (författare)
Fraunhofer Development Center X-ray Technology EZRT, Fürth, Germany
Takman, P. (författare)
Excillum AB, Kista, Sweden
Heinzl, C. (författare)
University of Applied Sciences Upper Austria, Wels, Austria
Holmberg, Anders (författare)
KTH,Biomedicinsk fysik och röntgenfysik,KTH Royal Institute of Technology, Stockholm, Sweden
Krumm, M. (författare)
Sauerwein, C. (författare)
RayScan Technologies GmbH, Meersburg, Germany
visa färre...
 (creator_code:org_t)
Institute of Physics Publishing (IOPP), 2015
2015
Engelska.
Ingår i: Journal of Instrumentation. - : Institute of Physics Publishing (IOPP). - 1748-0221 .- 1748-0221. ; 10
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The NanoXCT EU FP7 project [1] aims at developing a laboratory, i.e. bench top sized X-ray nano-CT system with a large field-of-view (FOV) for non-destructive testing needs in the micro- and nano-technology sector. The targeted voxel size is 50 nm at 0.175 mm FOV, the maximum FOV is 1 mm at 285 nm voxel size. Within the project a suitable X-ray source, detector and manipulation system have been developed. The system concept [2] omits the use of X-ray optics, to be able to provide a large FOV of up to 1 mm and to preserve the flexibility of state-of-the-art micro-CT systems. The targeted resolution will be reached via direct geometric magnification made possible by the development of a specialized high-flux nano-focus transmission X-ray tube. The end-user's demand for elemental analysis will be covered by energy-resolved measurement techniques, in particular a K-edge imaging method. Timepix [3] modules were chosen as the basis for the detector system, since a photon counting detector is advantageous for the long exposure times that come with very small focal spot sizes. Additional advantages are the small pixel size and adjustable energy threshold. To fulfill the requirements on field-of-view, a detector width > 3000 pixels was needed. The NanoXCT detector consists of four Hexa modules with 500 mu m silicon sensors supplied by X-ray Imaging Europe. An adapter board was developed to connect all four modules to one Fitpix3 readout. The final detector has an active area of 3072 x 512 pixels or approximately 17 x 3 cm(2). In this contribution we present the development of the Timepix based NanoXCT detector, it's application in the NanoXCT project for CT and material specific measurements and the current status of results.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Nyckelord

Detector design and construction technologies and materials
Inspection with x-rays
Detection of defects
Detector alignment and calibration methods (lasers
sources
particle-beams)
Physics
Fysik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy