MetalMUMPs resonator for acetone vapor sensing

Rabih, A. A. S. (författare)
Universiti Teknologi PETRONAS, MYS
Khir, M. H. M. (författare)
Universiti Teknologi PETRONAS, MYS
Ahmed, A. Y. (författare)
Universiti Teknologi PETRONAS, MYS
visa fler...
Mian, M. U. (författare)
Universiti Teknologi PETRONAS, MYS
Dennis, J. O. (författare)
Universiti Teknologi PETRONAS, MYS
Ahmed, M. G. A. (författare)
University of Gezira, SDN
Idris, Alamin (författare)
Universiti Teknologi PETRONAS, MYS
visa färre...
 (creator_code:org_t)
IEEE, 2017
2017
Engelska.
Ingår i: Proceedings of the 2017 IEEE regional symposium on micro and nanoelectronics (RSM). - : IEEE. - 9781509040292 ; , s. 5-9
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Acetone vapor monitoring is essential in workplace for human health and safety, where exposure to acetone concentration more than 176 parts per million (ppm) can cause damage to eyes, liver, kidneys and central nervous system. In addition, acetone in exhaled breath is known to be good biomarker for non-invasive screening of diabetes. The most common used acetone vapor sensors are based on metal oxide semiconductor sensors, which work at higher temperatures, and hence consume more power. This paper reports MetalMUMPs device for acetone vapor sensing for environmental monitoring. The device is based on electrothermal actuation and capacitive sensing using differential capacitance measurement technique. MS3110 universal capacitive readout circuit was used to readout the small change of the static capacitance when the device is actuated using 0.71 Vrms with a driving frequency range of 0.5 kHz-8 kHz. The output signal of the circuit is given as a voltage and it can be directly related to the capacitance change. The output voltage change was found to increase linearly with increasing the acetone vapor concentration from 100 ppm to 500 ppm with a concentration sensitivity of 0.65 mV/ppm.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Kemiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Chemical Engineering (hsv//eng)

Nyckelord

capacitance measurement;capacitive sensors;chemical sensors;readout electronics;resonators;metalMUMPs resonator;acetone vapor sensing;acetone vapor monitoring;human health;human safety;eyes;liver;kidneys;central nervous system;biomarker;diabetes;acetone vapor sensors;metal oxide semiconductor sensors;environmental monitoring;electrothermal actuation;capacitive sensing;differential capacitance measurement technique;MS3110 universal capacitive readout circuit;frequency 0.5 kHz to 8 kHz;Capacitance;Fingers;Resonant frequency;Temperature sensors;Valves;Sensitivity;MetalMUMPs resonator;Chitosan;Micro-rdevice
Chemical Engineering
Kemiteknik

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy